Description
One of a range of experiment modules that fi t to the Structures platform , this product helps students to understand how loads affect the horizontal reaction forces in a two-pinned arch. Students apply loads to hangers suspended from the arch, held between two supports. One support allows rotational movement only, acting as a pinned support. The other support allows translational movement, acting as a roller support. A load cell prevents the translation, while measuring the horizontal reaction due to the load. Each support includes pointers that work with the scale on the platform for accurate positioning. Students use textbook equations to predict the reaction forces due to the load, comparing them with measured results, and learn how to create the influence line and bending moment diagrams. This helps confirm the reliability of the textbook equations and the accuracy of the experiment results. This product includes additional masses so students may apply a uniformly distributed load (UDL) across the span of the arch for comparison of results with a single point load. The load cell connects to the USB interface hub of the Structures platform for computer display and data acquisition.
Learning Outcomes
- Horizontal reaction due to a varying single point load on a statically indeterminate structure
- Horizontal reaction due to a moving single point load on a statically indeterminate structure
- Horizontal reactions due to a uniformly distributed load on a statically indeterminate structure
- Influence lines and superposition
- Lines of thrust in an arch
- Graphical construction of a bending moment diagram for point loads
- The Secant assumption
- Maximum bending moments due to a load on an arch
Specifications
ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specification without prior notice.
Dimensions and weight:
Nett (assembled): 660 mm long x 100 mm front to back and 320 mm high and 5 kg
Approximate primary packed (with storage tray): 0.07 m3 and 7 kg
Space Needed: 500 mm x 600 mm, level bench or desk Items Included:
Two arch supports, holding an arch of 0.5 m span x 0.1 m height
Cable
Nine mass hangers
50 x 20 g masses
Storage tray
Comprehensive user guide
Operating Conditions
Operating environment:
Laboratory
Storage temperature range:
–25°C to +55°C (when packed for transport)
Operating temperature range:
+5°C to +40°C
Operating relative humidity range:
80% at temperatures < 31°C decreasing linearly to 50% at 40°C