If you are a college or university looking to setup a complete lab. Please contact us with your details for custom quotation. sales@aticoexport.com

Oscilloscope 50MHz

We are the leading manufacturer and supplier of Oscilloscope 50MHz. Now accepting bulk orders for government tenders in every major country around the globe.

Oscilloscope  50MHz

Technical Specifications                

Dual Trace

VERTICAL  : Channels : 2

Bandwidth : DC ~ 50MHz (-3dB)

Rise Time : <7ns Approx.

Sensitivity : 2mV/div ~ 10V/div (1-2-5 increments)

Accuracy : ±(3% x [Readout] + 0.1 div + 1mV)

Input Coupling : AC, DC & Ground

Input Impedance : 1MΩ ±2%, ~ 15pF

Polarity : Normal & Invert

Max. Input : 300V (DC+AC peak), CAT II

Waveform Signal Process : +, -, FFT

Offset Range : 2mV/div ~ 50mV/div : ±0.4V,  10mV/div ~ 500mV/div : ±4V  1V/div ~ 5V/div : ±40V,  10V/div : ±300V

Bandwidth Limit : 20MHz (-3dB)

Trigger :

Sources : CH1,  CH2,  LINE,  EXT

Modes : Auto, Normal, Single, TV, Edge, Pulse Width

Coupling : AC, DC, LF rej, HF rej, Noise rej,

Sensitivity : DC ~ 25MHz : Approx. 0.5 div or 5mV

25MHz ~ 50/70/100MHz : Approx. 1.5 div or 15mV

Ext. Trigger :

Range : ±15V

Sensitivity : DC ~ 25MHz : ~ 50mV;  25M ~ 50/70/100MHz : ~ 15mV

Input Impedance : 1MΩ±2%, ~ 16pF

Max. Input : 300V (DC AC peak),

Horizontal :

Range : 1ns/div ~ 50s/div (1-2-5 increments) : ROLL : 50ms/div ~ 50s/div

Modes : Main,  Window,  Window Zoom,  Roll,  X-Y

Accuracy : ± 0.01%

Pre-Trigger : 10 div max.

Post trigger : 1000 div

X-Y Mode :

X-Axis Input : Channel 1

Y-Axis Input : Channel 2

Phase shift : ±3° at 100 KHz

Signal Acquisition :

Real Time Sample Rate : 250MSa/s  max.

Equivalent Sample Rate : 25GSa/s  max.

Vertical Resolution : 8 Bits

Record Length : 4K Dots max.

Acquisition mode : Normal, Peak, Detect, Average

Peak Detection : 10ns ( 500ns/div ~ 50s/div)

Average : 2, 4, 8, 16, 32, 64, 128, 256

Cursor And Measurement :

Voltage Measurement : Vpp, Vamp, V avg, Vrms, Vhi, Vlo, Vmax, Vmin,

Rise Preshoot / Overshoot,  Fall Preshoot / Overshoot

Time measurement : Freq. Period, Rise Time, Positive Width, Negative Width, Duty cycle

Cursor measurement :  Voltage difference between cursors (ΔV)

Time difference between cursors (ΔT)

Display :

TFT LCD Type : 5.7 inch

Display Resolution : 234 x 320 Dots

Display Graticule : 8 x 10 divisions

Display Brightness : Adjustable

 

 

 

 

 

 

 

 

 

 