If you are a college or university looking to setup a complete lab. Please contact us with your details for custom quotation. sales@aticoexport.com

Control Unit for Wind Power Plant

We are the leading manufacturer and supplier of Control Unit for Wind Power Plant. Now accepting bulk orders for government tenders in every major country around the globe.

The Generation Of Power In Wind Power Plants Covers A Significantly Increasing Proportion Of Energy Needs Worldwide. Both The Conversion Of The Kinetic Wind Energy And The Use And Storage Of The Generated Electrical Power Are Crucial Aspects In This Context.

It Is A Compact Control Unit For The Mobile Wind Power Plant. The Electrical Energy From The Wind Power Plant It Is Fed Into The Stand-Alone System Of It, Which Is Independent From The Power Grid.

The Electrical Energy Is Stored Temporarily By Means Of A Charge Controller In An Accumulator Included In It. As Soon As The Accumulator Is Charged, The Excess Electrical Energy Is Dissipated In Fixed Resistors. This Overcharge Protection Is Triggered When The Defined End-Of-Charge Voltage Is Reached. It Is Indicated On The Charge Controller By Means Of An LED Lamp. The Wind Power Plant Will Continue To Run Under These Conditions, And Can Provide Electrical Energy Again Instantaneously When Needed.

Learning Objectives And Experiments

  • In Combination With The Wind Power Plant :
  • Conversion Of Kinetic Wind Energy Into Electrical Energy
  • Operating Behaviour Of A Wind Power Plant Under Real Weather Conditions
  • Components, Function And Setup Of A Stand-Alone System With A Wind Power Plant
  • Energy Balance Of A Stand-Alone System With A Wind Power Plant

Specification

  • Control Unit For Wind Power Plant In Stand-Alone Operation
  • Connections For Wind Power Plant And The Accumulator In On The Rear
  • Charge Controller With Overcharge Protection With Fixed Resistors
  • 2 Lamps As Electrical Loads (Consumers)
  • Detection And Display Of The Wind Velocity And Rotor Speed Of IT
  • Detection Of Current And Voltage At Different Points Of The Stand-Alone System
  • Additional Measuring Points For Current And Voltage Using The Laboratory’s Own Measuring Equipment

Technical Specification

  • Charge Controller
  • Nominal Voltage: 12V
  • Max. Charging Voltage: 14,2V
  • Max. Current: 40A
  • Control Procedure: PWM
  • Electrical Load (2 Lamps)
  • Voltage: 12VDC
  • Power: 55W Each
  • Measuring Ranges
  • Wind Velocity: 0,3…50m/S
  • Speed: 0…3000min-1
  • Voltage: 0…20VDC
  • Current: 0…35A
  • 230V, 50Hz, 1 Phase
  • 230V, 60Hz, 1 Phase
  • 120V, 60Hz, 1 Phase

 

Tell us Your Requirements

Sending your message...



Your Cart

Your Cart is Empty! Go Shopping